Backup power for a well pump or a sump pump: what a power station must handle
In a storm, the sump pump keeps the basement dry and the well pump is the water for the whole house. Both have electric motors, and a motor asks for several times its running power for a moment when it starts. That moment, not the battery, is what most often makes a backup fail.
First: 120 V or 240 V?
Look at the pump's nameplate, or at the pressure switch or control box of a well pump. Most sump pumps plug into a normal 120 V outlet. Many well pumps, especially submersible ones, are wired for 240 V.
- 120 V pump: it can run from a power station's AC outlet if the station's output and surge are high enough (table below).
- 240 V pump: the stations in the table list a 120 V output or do not publish their voltage, so none of them can run it. Two stations in HEA's catalog publish a 120/240 V split-phase output, the OUKITEL P5000 Plus and the Nature's Generator MyGrid 10K Gen 2, but HEA has not checked either one against a 240 V pump's start. A 240 V pump needs a setup that delivers 240 V, planned and connected by a licensed electrician; the whole-home guide compares those stations.
How the table reads
HEA's calculator counts a 1/3 HP sump pump at 800 W running and about 2,000 W to start, and a 1/2 HP well pump at 1,000 W running and about 3,000 W to start. A station gets a ✓ when its published continuous output covers the running power and its published surge covers the start. Your pump may need more: its manual or nameplate may list a starting (locked-rotor) current, and the station's surge must cover it.
| Model | Capacity | Output / surge | Sump 1/3 HP | Well 1/2 HP | Price |
|---|---|---|---|---|---|
| Anker SOLIX C1000 Gen 2 | 1,024 Wh | 2,000 W / 3,000 W | ✓ | ✓ | See in HEAAnker SOLIX official store |
| FOSSiBOT F1800 | 1,024 Wh | 1,800 W / 3,600 W | ✓ | ✓ | See in HEAFOSSiBOT official store |
| EcoFlow DELTA 3 | 1,024 Wh | 1,800 W / 3,600 W | ✓ | ✓ | See in HEAEcoFlow official store |
| EcoFlow DELTA 3 Plus | 1,024 Wh | 1,800 W / 3,600 W | ✓ | ✓ | See in HEAEcoFlow official store |
| OUKITEL P1000 Plus | 1,024 Wh | 1,800 W / 3,600 W | ✓ | ✓ | See in HEAOUKITEL official store |
| ALLPOWERS P1800 | 1,024 Wh | 1,800 W / 3,600 W | ✓ | ✓ | See in HEAALLPOWERS official store |
| ALLPOWERS S2000 Pro | 1,451 Wh | 2,400 W / 4,000 W | ✓ | ✓ | See in HEAALLPOWERS official store |
| ALLPOWERS R2500 v2 | 1,920 Wh | 2,500 W / 4,000 W | ✓ | ✓ | See in HEAALLPOWERS official store |
| Jackery Explorer 2000 v2 | 2,042 Wh | 2,200 W / 4,400 W | ✓ | ✓ | See in HEAJackery official store |
| Anker SOLIX C2000 Gen 2 | 2,048 Wh | 2,400 W / 4,000 W | ✓ | ✓ | See in HEAAnker SOLIX official store |
| FOSSiBOT F2400 | 2,048 Wh | 2,400 W / 4,800 W | ✓ | ✓ | See in HEAFOSSiBOT official store |
| OUKITEL P2001 Plus | 2,048 Wh | 2,400 W / 4,800 W | ✓ | ✓ | See in HEAOUKITEL official store |
| Anker SOLIX F3000 | 3,072 Wh | 3,600 W / 7,200 W | ✓ | ✓ | See in HEAAnker SOLIX official store |
| Nature's Generator L3600 | 3,072 Wh | 3,600 W / 7,200 W | ✓ | ✓ | See in HEANature's Generator official store |
| ALLPOWERS R4000 | 3,456 Wh | 3,600 W / 6,000 W | ✓ | ✓ | See in HEAALLPOWERS official store |
| EcoFlow DELTA 3800 Gen4 | 3,763 Wh | 3,600 W / 7,200 W | ✓ | ✓ | See in HEAEcoFlow official store |
| FOSSiBOT F3600 Pro | 3,840 Wh | 3,600 W / 7,200 W | ✓ | ✓ | See in HEAFOSSiBOT official store |
| Anker SOLIX F3800 | 3,840 Wh | 6,000 W / 9,000 W | ✓ | ✓ | See in HEAAnker SOLIX official store |
Prices come from the official US stores and change often; the store always shows the current one. Output and surge are the manufacturers' published figures as HEA reviewed them. Stations in HEA's catalog that publish no surge figure are left out, because their start cannot be checked.
How much battery?
Pumps run in short cycles, so their energy is small next to their start. In the calculator, each pump runs about an hour a day in total: about 0.8 kWh a day for the sump pump and 1 kWh for the well pump. In a heavy rain a sump pump can run far more than that, so a station of 2 kWh or more is a sensible floor when the sump pump is the reason you are buying, and 3 to 4 kWh if the refrigerator shares it.
Before the storm
- Test it once while the power is on: unplug the pump, plug it into the charged station and let it start a few times.
- Plug the pump straight into the station. Thin or long extension cords make the start harder.
- Never connect a station to the home's wiring yourself. Running a hard-wired well pump from a station, or feeding a circuit, needs a transfer switch or an inlet installed by a licensed electrician.
Not ready to buy today? Get the real price drops by email from HEA's price tracker.
Home Energy Advisor is an independent pilot project. Some store links on this site are affiliate links: HEA may earn a commission on eligible purchases, and commissions do not change how equipment is compared. A favorable estimate does not certify an installation; connecting to a home electrical panel requires a qualified professional.